1dl code on goodman furnace - May 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return.

 
GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice. Cars for sale by owner near me under dollar2000

ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.Dec 19, 2022 · Goodman furnace isn’t blowing hot air. First, check your thermostat if your Goodman furnace isn’t blowing hot air. It should be set to “auto” and “heat.”. If it’s set to “on,” your fan will blow air constantly, even when it’s not actively heating. Next, check your air filter. You should change your furnace air filter regularly. Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.Turn off power to the furnace and check the inlet gas pressure. Minimum Pressure = 5" w.c. for Nat. Gas, and 11" w.c. for Propane. No or Low Pressure = Bad Meter or Regulator; Normal Pressure ⇒ Continue; Re-apply power to the furnace and activate a call for heat. Make sure the inlet gas pressure stays above minimum when the gas valve energizes.Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC TechnicianHow to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter. Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... Remove the access panel on your Trane furnace. Locate the dirty air filter. It should be near the return air duct or the blower chamber’s entrance. Remove the old air filter and slide in a new one. Ensure that signifiers indicate that the new filter is installed correctly. Replace the panel or door to your Trane furnace.RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.Feb 25, 2023 · Goodman error code 7P1 is IDL This one covers the IFC error codes for most Trane furnaces. This video is part of the heating and cooling series of training videos made to accompany my we...CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. goodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read moreTurn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.4th of July Deals - Purchase Your HVAC Equipment Direct ... Aug 16, 2023 · Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, orfailed ... Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC TechnicianGet professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long.My goodman furnace's diagnostic display reads 88. I was away for work and my girlfriend said it was reading e5 so I got her to cut power and change 3 amp fuse. Now it says 88 and im stumped. Furnace d … read moreNov 14, 2022 · operating both with a Nest Smart thermostat about 8-10 yrs old…heating program always ran fine with Lennox…now the program doesn't always work…thermostat is lit up showing it's calling for heat but furnace is not running…I turn thermostat off and back on and furnace starts to run… Oct 12, 2017 · Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating. Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.Jan 4, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ... Nov 30, 2019 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... October 28, 2021 Goodman furnaces have a display panel with a built-in trouble-code that uses LED lights to show the homeowner that there is a malfunction of some sort. What do these error codes mean and is there anything that you can do to fix these problems? Here is everything that you need to know. Goodman Furnace Error CodesERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil. Turn off power to the furnace and check the inlet gas pressure. Minimum Pressure = 5" w.c. for Nat. Gas, and 11" w.c. for Propane. No or Low Pressure = Bad Meter or Regulator; Normal Pressure ⇒ Continue; Re-apply power to the furnace and activate a call for heat. Make sure the inlet gas pressure stays above minimum when the gas valve energizes.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read moreMar 23, 2017 · Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43. ERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil.The CoolCloud HVAC application allows contractors to connect and communicate wirelessly via Bluetooth with Goodman and Amana premium air handler and furnace control boards. This provides a more efficient means for servicing and maintaining equipment, making configuration adjustments, gaining equipment status, performing diagnostics, viewing ... Last Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components.AC furnace brands AC furnaces, also known as central air conditioning systems, are important to home comfort and energy efficiency. Many AC furnace brands are on the market, each with strengths and weaknesses. Trane is a popular AC furnace brand known for its...4th of July Deals - Purchase Your HVAC Equipment Direct ...The Goodman furnace error code 1dl is a common error code associated with Goodman furnaces that indicates a problem with the hot surface ignitor. When this error code appears, it usually indicates that the hot surface ignitor has failed and needs to be replaced. This article will provide an overview of this error code and discuss how to ...The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up. Instructions: 1. Select the brand from the drop down menu 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. © 2011 Goodman Manufacturing Company, LP. All rights reserved.Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.Nov 30, 2019 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... My goodman furnace's diagnostic display reads 88. I was away for work and my girlfriend said it was reading e5 so I got her to cut power and change 3 amp fuse. Now it says 88 and im stumped. Furnace d … read moregoodman furnace codes The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart. Goodman is one of the biggest names in home heating and energy efficient home comfort. View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14... Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. Feb 25, 2023 · Goodman error code 7P1 is IDL Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating.Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.Sep 29, 2022 · If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3. AMANA & GOODMAN FAULT CODES. 1. One led flash that stays on continuously = No signal from thermostat. Turn off power and check connections. 2. One led that flashes = Furnace lockout after three attempts to fire. Must be reset by lowering it for twenty seconds and then raise it back. After one hour furnace will reset itself. 3.CODE: b9. RESULT: Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match. CODE: d0. RESULT: Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data. CODE: d1.The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up. Some simple Diy troubleshooting a Goodman furnace with no flame and the computer board putting out a number 1 flash code.Amazon link to Great products that e...Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.goodman air conditioner error codesHow to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter. FIX: Adjust the gas pressure according to the information available to you. CODE: Eight LED flashes. PROBLEM: This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. FIX: Replace the igniter or check the ground wiring for defects. CODE: Nine LED flashes.Oct 12, 2017 · Model of the furnace: Keeprite high efficiency gas furnace Thermostat: Honeywell 4110 PRO Thermostat wiring: 4 wires [No C wire] Heating and cooling: yes I bought a new house and the furnace is one year old. Due to renovations, no one lived here so not sure it has been used. temperatures fell and I started using heating. Code 1-3: Indicates that a limit flame switch problem that normally auto-resets after 3 hours. Code 1-4: Represents an ignition problem. However, the furnace will auto-reset after some hours. Code 2-1: This is a sign of gas heating lockout. You need to check if the gas valve wiring is correct.- In short: check your fuse on the circuit board. If it's tripped, replace it. I got this 5 amp fuse on Amazon: https://amzn.to/3O5JUko and here's the Nest t...Goodman HVAC unit’s require registration with them to track the warranties. Registration is also required to get the extra additional warranty benefits. Warranty Registration. Most HVAC manufacturers including Goodman, require homeowner to register their Air Conditioner, Furnace and/or Heat Pump in order to get the extra years of their warranty.The controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not UsedOpen the gas valve fully in a counterclockwise motion to make sure the gas supply is turned on. Increase the temperature on the thermostat, and turn the mode to "Heat" after making sure the vents are all clear of blockages. Disconnect the power to reset the furnace, and contact Trane if necessary.Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace... A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre...I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace.ERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil. Open the gas valve fully in a counterclockwise motion to make sure the gas supply is turned on. Increase the temperature on the thermostat, and turn the mode to "Heat" after making sure the vents are all clear of blockages. Disconnect the power to reset the furnace, and contact Trane if necessary.Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.Aug 23, 2023 · Last Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components. No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... Aug 16, 2023 · Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, orfailed ... View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14... Hi just hooked up my Goodman furnace and as soon as I put the power on the 3:00 a.m. fuse blue. AnyHi just hooked up my Goodman furnace and as soon as I put the power on the 3:amp. fuse blew. Any sugg … read morePurchase Your HVAC Equipment Direct | Goodman AC And Furnace ... How to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter.

4th of July Deals - Purchase Your HVAC Equipment Direct ... . Used trucks under dollar4000 near me

1dl code on goodman furnace

Nov 29, 2014 · A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre... GMES80-U. Goodman furnace features: Multi-speed motor, ultra-low NOx, fault code LED output, quiet draft inducer. Pros and cons: With an 80 percent AFUE rating, this is one of Goodman’s least efficient furnaces. This is a single-stage model, which means it is a less energy efficient but more affordable option.GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC noticegoodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read morePurchase Your HVAC Equipment Direct | Goodman AC And Furnace ...4th of July Deals - Purchase Your HVAC Equipment Direct ...My goodman furnace's diagnostic display reads 88. I was away for work and my girlfriend said it was reading e5 so I got her to cut power and change 3 amp fuse. Now it says 88 and im stumped. Furnace d … read moreFeb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace...ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.Goodman is one of the biggest names i...Aug 23, 2023 · Last Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components. Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace... I have a Amana AM9C960603ANAA. I'm getting 2 codes on the LCD display. First is 1dl and the second one is EE5. What do - Answered by a verified HVAC TechnicianGet professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long.Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC TechnicianOctober 28, 2021 Goodman furnaces have a display panel with a built-in trouble-code that uses LED lights to show the homeowner that there is a malfunction of some sort. What do these error codes mean and is there anything that you can do to fix these problems? Here is everything that you need to know. Goodman Furnace Error CodesThe Goodman furnace error code 1dl is a common error code associated with Goodman furnaces that indicates a problem with the hot surface ignitor. When this error code appears, it usually indicates that the hot surface ignitor has failed and needs to be replaced. This article will provide an overview of this error code and discuss how to ...Trane furnace code 1dl. Troubleshooting a Trane furnace with code 1DL is a common challenge homeowners face. Code 1DL stands for “Inadequate Diffuser Pressure Switch Closure” and can occur due to problems with the furnace blower motor, evaporation motor, heat exchanger or other related components..

Popular Topics